SKU
HYXMMPD-60-3Z
MAPA MPD-60-3Z, Stainless Steel Pedestal with Square D Disconnect, 600v-60amp, 3 Blades
The MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides local electrical service disconnect at roof-mounted equipment.
•Pedestal – 4” X 4” 11 gauge 304 stainless square tubing
•Solid welded stainless cap tops off...
Read More •Pedestal – 4” X 4” 11 gauge 304 stainless square tubing
•Solid welded stainless cap tops off...
The MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides local electrical service disconnect at roof-mounted equipment. The stainless shroud with an integrally welded deck flange enables a positive weather-tight flash of the unit to the roof membrane without additional flashing or pitch-pan. The need to interrupt electrical service remotely in the case of equipment change-out can be avoided since the service disconnect is mounted adjacent to rather than onto the equipment.
- Pedestal – 4” X 4” 11 gauge 304 stainless square tubing
- Total length indicated by suffix xx + yy
- Solid welded stainless cap tops off the shroud
- Under deck flange – welded 16 gauge sheet metal – black painted with anchor bolts and trim to secure pedestal to roof structure.
- Florida Product Approval #FL21083
- The standard stainless steel shroud extends a minimum of thirty-six inches above the roof line and an additional twelve inches beneath the roofline shroud. This permits the unit to be securely fastened to the roof structural member by securing the under-deck mounting flange to a welded deck flange.
- The underdeck flange is provided with fastening hardware, enabling the installer to secure it against the shroud and onto a deck flange.
- Pedestals are furnished completely assembled with safety switch and wiring leads.
- Liquid-tight steel core flexible conduit protects the equipment's electrical service wire cable leads.
- Leads for connection to the power source below the roofline are shielded in metal conduit.
- Wiring service for the GFCI is provided in a separate flexible conduit.
- Wiring and Conduit sizes are according to industry standards and NEC.
- All connections exposed to the weather are made liquid-tight.
- Optional termination cables are available in five (5) or ten (10) foot lengths.
- All safety switch disconnects are furnished with NEMA 3R Rainproof enclosure.
- The switch is provided with handle suitable for padlocking in the OFF position.
- The defeatable front accessible door prevents the switch from opening when in the ON position or turning ON when the door is open.